搜索结果: 1-7 共查到“工程结构 WIND”相关记录7条 . 查询时间(0.046 秒)
An Integrated Monitoring System for Life-Cycle Management of Wind Turbines
life-cycle management structural health monitoring wind turbines multi-agent technology
2015/6/30
With an annual growth rate of about 30%, wind energy systems, such as wind turbines, represent one of the fastest growing renewable energy technologies.Continuous structural health monitoring of wind ...
Integration of structural health and condition monitoring into the life-cycle management of wind turbines
Integration structural health condition monitoring life-cycle management wind turbines
2015/6/30
Cost-efficient operation and maintenance of wind turbines is among the major concerns for manufacturers, owners, and operators. Integrating structural health monitoring (SHM) into life-cycle managemen...
Implementing a Multiagent-Based Self-Managing Structural Health Monitoring System on a Wind Turbine
Implementing Multiagent-Based Self-Managing Structural Health Monitoring System Wind Turbine
2015/6/30
Deteriorations, increasing costs and burdens of maintenance work as well as recent collapses of civil engineering structures underscore the need for robust, cost-effective structural health monitoring...
Simulation and Modelling of Smart Beams with Robust Control Subjected to Wind Induced Vibration
Smart Structures Finite Element Formulation Uncertainty Robust Performance Reduced Order Control
2013/1/31
This paper presents some recent developments in modelling and numerical analysis of piezoelectric systems and controlled smart structures based on a ?nite element formulation with embedded control. Th...
Discussion of “Tornado-Induced Wind Loads on a Low-Rise Building” by F. L. Haan Jr., Vasanth Kumar Balaramudu, and P. P. Sarkar
Tornado-Induced Wind Loads Low-Rise Building
2014/4/10
Haan et al. present novel research regarding the loads on low-rise buildings under tornadic winds, combining a large and significant matrix of test data with useful analysis. The observation that the ...
Simple quasi-static treatment of wind loading, which is universally applied to design of typical low to medium-rise structures, can be unacceptably conservative for design of very tall buildings. On t...
Estimating 3-second and maximum instantaneous gusts from 1-minute sustained wind speeds during a hurricane
Peak wind hurricane gusts roughness length
2009/1/14
Formulas for estimating 3-second and maximum instantaneous gusts from 1-minute sustained mean wind speeds are derived for operational applications. These formulas are verified by measurements recorded...