搜索结果: 1-12 共查到“化学工程 MEASUREMENT”相关记录12条 . 查询时间(0.05 秒)
Electrocatalytic measurement of H2O2 concentration using bis(N-2-methylphenyl-salicyldenaminato)copper(Ⅱ) spiked in a carbon paste electrode
Electrochemical behavior Bis(N-2-methylphenyl-salicyldenaminato)copper(Ⅱ) complex Hydrogen peroxides Electrocatalytic reduction
2014/3/11
The electrochemical behavior of a bis(N-2-methylphenyl-salicyldenaminato)copper(Ⅱ) complex spiked in a carbon paste electrode (BMPSCu-CPE) and its electrocatalytic reduction of H2O2 were examined usin...
Electrocatalytic measurement of methionine concentration with a carbon nanotube paste electrode modified with benzoylferrocene(图)
Methionine Electrocatalysis Carbon nanotube Chemically modified electrode Voltammetry Benzoylferrocene
2013/9/25
A benzoylferrocene modified multi-wall carbon nanotube paste electrode for the measurement of methionine (MET) concentration is described. MET electrochemical response characteristics of the modified ...
Measurement and Correlation of Liquid–Liquid Equilibrium Data for Ethanol–Water–KF and Ethanol–Water–K2CO3 Systems
ethanol–water–KF NRTL equation UNIQUAC equation correlation
2009/11/16
The liquid–liquid equilibrium data for two ternary systems, ethanol–water–KF and ethanol– water–K2CO3, were determined at 25℃. Experiments show that by adding KF or K2CO3 into the ethanol–water system...
Measurement of Mass Transfer Coefficients and Their Modelling of Continuous Counter-Current Aqueous Two-Phase System in a Packed Extraction Column
aqueous two-phase system continuous countercurrent extraction mass transfer coefficient
2009/4/28
Overall dispersed side volumetric mass transfer coefficients forprotein and amino acids were measured in continuous countercurrentPEG4000/KHP aqueous two-phase systems in a 57 mm I.D. packed extract...
Measurement of Isoplethic Vapor-Liquid Equilibrium Data by Using Inclined Ebulliometer
vapor-liquid equilibrium ebulliometer quasi-static method
2009/4/28
Isoplethic VLE data for the systems benzene-hexane at 9 different compositions in the temperature range from 298K to 331K, chloroform-benzene at 11 different compositions in the temperature range from...
Measurement of Concentration Fields near the Interface of a Rising Bubble by Holographic Interference Technique
测量法 全息干涉技术 泡沫 传质
2009/4/28
Measurement of Concentration Fields near the Interface of a Rising Bubble by Holographic
Interference Technique.
Local Measurement of Gas-Liquid Bubbly Flow with a Double-Sensor Probe
two-phase bubbly flow double sensor probe signal processing
2009/4/28
Local Measurement of Gas-Liquid Bubbly Flow with a Double-Sensor Probe.
Detachment Size Measurement of Two Interacting Bubble Plumes Formed at Neighboring Needles Using an Acoustic Method
detachment size determination sound pressure pulses
2009/4/23
size determination with an acoustic method has been carried out for two interacting bubble plumes formed at neighboring needles in quiescent water. Two sets of needle pairs, one with 1.5mm and 0.8mm...
Electrochemical measurement of flow parameters in dilute solution
electrochemical measurement ionic migration
2009/4/22
Electrochemical measurement of flow parameters in dilute solution.
The Measurement of Oil, Gas and Water Flowrates in Three-Phase Slug Flow
measurement flowrate phase flow slug flow
2009/3/20
The Measurement of Oil, Gas and Water Flowrates in Three-Phase Slug Flow.
Measurement of residual stress in plasma-sprayed TBC with a gardient of porosity and chemical composition
Metallic alloys Thin&thick coatings Degradation
2010/2/10
Purpose: The purpose of the research was identification of the residual stress in the top coat of different type of thermal barrier coating with gradient of chemical composition and gradient of porosi...
期刊信息
篇名
Enzymatic activity measurement of phospholipid hydroperoxide glutathione peroxidase by capillary electrophoresis
语种
英文
撰写或编译
撰写
作者
Qinhua Ru,Guoan Lou,Zebin Wang and Jinyuan Liu
第一作者单位
Tsinghu...