搜索结果: 1-6 共查到“海洋科学 Fine-Structure”相关记录6条 . 查询时间(0.125 秒)
The Effect of Internal Wave Strain on Vertical Spectra of Fine-Structure
Internal Wave Strain Fine-Structure Vertical Spectra
2009/4/2
Vertical spectra of temperature perturbations are due to (i) internal wave displacement in the mean profile and (ii) fine-structure that would still be measured in the absence of internal waves. The f...
Interpretation of Internal Wave Measurements in the Presence of Fine-Structure
Internal Wave Measurements Fine-Structure
2009/3/26
Philips has pointed out that the measurement of the internal wave spectrum and coherence in a stratified medium is distinctly altered when the profile contains fine-scale layers. Garrett and Munk demo...
Fine-Structure Contamination of Moored Temperature Sensors:A Numerical Experiment
Fine-Structure Contamination A Numerical Experiment Moored Temperature Sensors
2009/3/24
Using an inverse fast Fourier transform technique, numerical calculations have been made in order to study the contamination of moored temperature measurements of internal waves by passive temperature...
Internal Wave Spectra in the Presence of Fine-Structure
Internal Wave Spectra Fine-Structure
2009/3/9
Phillips has shown that an undulating motion of a layered medium relative to a measuring instrument will result in a σ−2 spectrum (frequency or wavenumber) over a bandwidth determined by the thi...
The Fine-Structure of Nearshore Tidal and Residual Circulations Revealed by H.F. Radar Surface Current Measurements
Ocean Surface Current Radar Residual Circulations Nearshore Tidal
2009/1/7
Using the Ocean Surface Current Radar (OSCR) developed by the Rutherford–Appleton Laboratory (UK), 30 days of synoptic hourly surface current vectors were obtained for 84 locations within a nearshore ...
Fine-Structure Contamination: Observations and a Model of a Simple Two-Wave Case
Fine-Structure Contamination Model Simple Two-Wave Case
2008/7/31
Internal waves advect vertical structure past Eulerian (fixed depth) sensors, leading to “fine-structure contamination,” wherein the intrinsic frequency spectrum is Doppler shifted by the advective mo...